Basic Info.
Product Description
An Advanced Industrial Air Shower System with Intelligent Dust Removal Functionality represents the pinnacle
of technology for maintaining strict cleanliness standards in controlled manufacturing environments. This
sophisticated equipment is specifically designed to prevent the ingress of contaminants into critical zones such
as Class100K to Class 1 cleanrooms found in industries including semiconductors, pharmaceuticals,
microelectronics,and medical device manufacturing.
Key Features:
Smart Sensing and Control: The system integrates advanced sensor technology that detects the presence
of personnel or objects, triggering an automated cleaning cycle. It may also feature intelligent algorithms that
adapt the air shower duration, pressure, and direction based on detected levels of contamination.Precision Airflow: High-velocity HEPA-filtered air jets strategically target all surfaces of the individual or
material, dislodging and removing microscopic particles down to 0.3 microns with near-perfect efficiency.Intelligent Dust Detection: In some advanced models, there may be built-in particle detection capabilities that
assess the effectiveness of the decontamination process and adjust airflow patterns accordingly.HEPA Filtration: Ensuring the highest level of cleanliness, the system uses multi-stage HEPA filters that trap
and eliminate even the smallest airborne particles, preventing them from recirculating.
Parameter/model | AS-1 | AS-2 | AS-3 |
Filter efficiency | ≥99.99%@0.3μm | ||
Spraying wind speed | ≥25 | ||
Shower time | 0-99 adjustable | ||
Number of nozzles | 12 pieces | 16 pieces | 18 pieces |
Dimension of shower area | 800x900x2000 | 800x1200x2000 | 800x1900x2000 |
Overall dimension(mm) | 1300x1000x2150 | 1300x1300x2150 | 1300x2000x2250 |
Chassis | Stainless steel plate | ||
Power supply | AC, 3N, 380V ±10%, 50Hz±2Hz | ||
Rated power consumption (W) | 1500 | 2000 | 3000 |
Weight (kg) | 500 | 700 | 1000 |
Production description
This is a kind of local purifying equipment, fixed on the partition between clean room and unclean room. It is used for shower
and removing dust when personnel or objects entering into clean area. Effectively reduce dust source from entering into clean
area after used, and keep clean area in normal working state. Shower way: single-side shower, double-side shower, three-side
shower, top shower.
Specifications
1. Photoelectric control, automatic shower.
2. Circulated air design keeps shower area clean in non-shower state.
3. Double doors adopt electric interlocking to force shower; double doors may be made as automatic movable door.
4. Made as negative pressure and anti-exploding air shower according to users' requirement.
5. Equipped with the device to remove static
6. Carry on air brake, cushion type and other particular design, manufacturing.